Just a quick heads up to a couple of problems I had over the weekend on the Solie scenarios. Anyway one the routers needed to be set up a having two sub interfaces, one point-to-point, one multipoint. On the PTP I mapped the wrong DLCI to it and even though I removed the statement and rebooted, it would not remove it. I needed to remove the subinterface and reboot then recreate the subinterface with the correct DLCI. Also I had a problem with another DLCI not being seen by the spoke router. This router's serial interface line protocol was also going up down. I suspected missing LMI and that was the case. It turns out that in recabling for the new lab, I bent one of the pins on the serial over. Anyway these two things cost some time so if I can save anyone grief with similar problems great. Otherwise I learned a few things which is the whole point of this.