I am installing a cisco based network with 3548s at access layer and 6506s
at the collapsed core . I am using dual 6506s for redundant links from 3548s
. I am using 4x1000BaseSx links between the two 6506s which are bundled
together(Gigabit etherchannel) all the 3548 > 6506s links and the 6506 >
6506 link are ISL trunks . I plan to use PVST and to make one 6506 the root
for some vlans and the other 6506 the root for the rest so that I can share
the load accross the redundant links from 3548 > 6506s.
And what I plan to do is to use HSRP for transparent layer 3 failover of the
clients from one 6506 to the other in case of the failure of one of the
3548's uplinks.
What I am confused about is this. STP will block one of the uplinks from
3548 > 6506 for each vlan. so how will the HSRP enabled vlan interfaces on
the two 6506 switches will be able to negotiate HSRP ?
Any clues ?




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=54189&t=54189
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to