Maybe you don't need to change your cable at all. DCE vs DTE is significant
at layer 1 for clocking issues. There is also DCE DTE at layer 2 for Frame
Relay purposes. The layer 1 DCE does not have to be on the same box as the
layer 2 DCE.

However if you really want another cable try Pacific Cable.

> -----Original Message-----
> From: Reza Sharifi [mailto:[EMAIL PROTECTED]]
> Sent: Tuesday, November 26, 2002 7:46 AM
> To: [EMAIL PROTECTED]
> Subject: Cisco DTE/DCE Cable [7:58103]
> 
> 
> I am looking for the pinouts for DB60 (DTE) to DB50 (DCE).  
> The cable is
> configured as DB60 (DTE) to DB50 (DCE).  I need to switch it 
> due to device
> configuration issues. (my 2522 is my frame relay switch and 
> need to be DCE)
> Can someone point me in the right direction.  I check
> CCO, but have not been able to find this particular configuration.
> 
> Thanks in advance.
> 
> Reza