Do a show cdp neighbor and verify that the both endpoints are where you think they are. Obviously, the ACTIVE side in the output below is where you think it is, but I'd bet money that the opposite endpoint is not r1 as shown below, or at least not on s0.
On R1, did you move your cable from Serial0 to another interface? Or did you move the cable to an entirely different router and forget about it? Or, did you accidentally configure two different routers with the same hostname and you're looking at the wrong one? :-) There must be an explanation, I'm just throwing out weird ideas in case one of them is right. John >>> "McHugh Randy" 2/14/03 1:14:51 PM >>> Happy Valentines everyone I have a deleted PVC that still works to connect through a frame switch to another router. Anyone else seen this? Here is the config r1#sh frame pvc 401 PVC Statistics for interface Serial0 (Frame Relay DTE) DLCI = 401, DLCI USAGE = LOCAL, PVC STATUS = DELETED, INTERFACE = Serial0 input pkts 0 output pkts 0 in bytes 0 out bytes 0 dropped pkts 0 in FECN pkts 0 in BECN pkts 0 out FECN pkts 0 out BECN pkts 0 in DE pkts 0 out DE pkts 0 out bcast pkts 0 out bcast bytes 0 pvc create time 16:43:18, last time pvc status changed 16:43:07 r1#ping 150.100.251.2 Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 150.100.251.2, timeout is 2 seconds: !!!!! Success rate is 100 percent (5/5), round-trip min/avg/max = 68/68/68 ms r1# r4#sh frame pvc 401 PVC Statistics for interface Serial0 (Frame Relay DTE) DLCI = 401, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0 input pkts 1020 output pkts 24 in bytes 288926 out bytes 2884 dropped pkts 0 in FECN pkts 0 in BECN pkts 0 out FECN pkts 0 out BECN pkts 0 in DE pkts 0 out DE pkts 0 out bcast pkts 14 out bcast bytes 1844 pvc create time 16:46:36, last time pvc status changed 16:45:46 r4#ping 150.100.251.1 Type escape sequence to abort. Sending 5, 100-byte ICMP Echos to 150.100.251.1, timeout is 2 seconds: !!!!! Success rate is 100 percent (5/5), round-trip min/avg/max = 68/68/68 ms r4# It shows 401 is active on one side and deleted on the other but I can ping accross to and from both sides accrose the switch. How can i get rid of that deleted pvc and make it active? Thanks Randy Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=63059&t=63055 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]