Hi all, while practicing frame-relay lmi-n39x commonds, i can not make the commonds work as they are supposed to be.
Scenario: frame-relay switch RA on RA, use lmi autosense. basic FR function works fine, following config is abstract only serial 0 encapsulation frame-relay frame-relay interface-dlci 401 ip address 150.50.24.2 255.255.255.0 frame-relay lmi-n391dte 3 frame-relay lmi-n392dte 2 frame-relay lmi-n393dte 2 keepalive 10 If "debu frame lmi" is turned on, i would expect every 30 seconds, 3 status requests will be sent out serial0 as a result of "frame-relay lmi-n391dte 3" and "lmi autosense". But i can only see one status request is sent. Tried shut/no shut interface, etc to no vail. Any idea how these commands affect frame relay behaviors? Thanks Paul Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=63120&t=63120 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]