Dear wise man,

First of all ,I think there's a more polite way we can discuss such issues
with each other.

Second none of those S register parameters is related to the modem
compression

S27 --------> enable/disable V.25 calling tone
S28----------> Guard tone
S30-----------> Max connect rate
S43-----------> V.34 carrier frequency

The parameters related to compression are:

S21 ---------> specify permited methods of data compression.

but I need to know the value of S21 to enable compression (S21=??)

   Regards,
   Mohamed


""Chivertison Micheal""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> are u stupid man?
> it is very very easy
> modemcap entry elkomy s27=12s28=12s30=13&&s43=67
> interface group-async 0
> ip unnumbered fastethernet x/x
> encapsulation ppp
> group-range x/x y/y
> compress stac
> ip tcp header-compression




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=63265&t=63253
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]