I am not sure how to overcome a potential problem. 
I have a BGP feed from an upstream provider that is a multi-hop. I am
concerned that if that neighboring router goes down I will still be sending
traffic out to him. The Interface will not go down since the circuit does
not term on the BGP router but a colocated router. I do not want to have to
wait 3 minutes for the BGP timer to expire. That will be 3 minutes of
traffic passed to a dead router.

Is there any other method (besides reducing the timer) to overcome this?