I am not sure how to overcome a potential problem. I have a BGP feed from an upstream provider that is a multi-hop. I am concerned that if that neighboring router goes down I will still be sending traffic out to him. The Interface will not go down since the circuit does not term on the BGP router but a colocated router. I do not want to have to wait 3 minutes for the BGP timer to expire. That will be 3 minutes of traffic passed to a dead router.
Is there any other method (besides reducing the timer) to overcome this? thanks, jim Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=63920&t=63920 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]