Yes, it's called Remote SPAN but it only works on the CatOS based switches.
The source, the destination and everything in between must be CatOS based in
order for this to work.

Aurelian Georgescu


-----Original Message-----
From: Martin J. [mailto:[EMAIL PROTECTED] 
Sent: Tuesday, March 11, 2003 9:08 AM
To: [EMAIL PROTECTED]
Subject: Switch Monitoring via Trunk on Cat [7:65045]

Hi All

Is there a way to set up a span (monitoring) port via a link or a trunk?
The meaning is, that the port I like to monitor is on a catalyst in an other
building.

Thanks for your help

Martin




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=65057&t=65045
--------------------------------------------------