We are running in-band with 3140 hardware, one CAS and one CAM, and have 33 wildcard filters (I just counted) for all of our Game Console Mac Addresses...I was not aware of a limit of 32 at all...
From: Cisco Clean Access Users and Administrators [mailto:[email protected]] On Behalf Of Schwind, Dennis C. Jr. Sent: Sunday, September 12, 2010 9:13 PM To: [email protected] Subject: Hello, How many CCA shops are extensively using wildcard MAC address filtering for in band deployments with 3140 appliances? We attempted this and paid a pretty heavy price, eventually causing us to abandon the practice. The symptom was CAS units disconnecting from the CAM. Cisco has stated there is a 32 wildcard limit. I was just curious to see how others have fared attempting this. Dennis Schwind Senior Security Engineer 513 529-9670 Miami University Oxford, Ohio