Hi, On 04 Feb 2011, at 08:45, [email protected] wrote:
> 1)Is it ever possible to write an element with more than one (say three) > PUSH ports for both input and output?. > i tried to create an element with 1/1 pull configuration and initialized > the timer too. > > but the code in the run_timer() method is never executed... > i was trying to reset a packet counter (in the push() method) periodically > to zero. > > This should be possible. Please publish your minimal code here, so we can help you fix it. > 2)Is it possible to have more than one OUTPUT ports for a PULL processed > element?. If so should all output ports except one be agnostic?. > we only have to 'return' the packet's pointer or null pointer in pull > processing. > how do we make forward the packet through a specific output port? Yes that is possible too, and all ports can be pull. As you can see in the signature of the pull function at <http://read.cs.ucla.edu/click/doxygen/class_element.html#ce8c7b8b37f177b9a9cc024d8b64f3a3>, the integer specifies the port which is pulled. regards, Bart _______________________________________________ click mailing list [email protected] https://amsterdam.lcs.mit.edu/mailman/listinfo/click