Hi Diana, The console would pop up automatically if the console window is open when the checkpoint is taken.
Just type: 'client_con0.open' to open the client machine console and 'server_con0.open' to open the server machine console. You should also make sure that you have xterm support on the machine, which you run the workloads. To test it, you can type 'xterm' before starting simics. If you see a window, it means that you have the correct settings to see the simics console. You can close that window afterwards. A final note, I don't know what your goal is but, if you just want to change the workloads settings or browse the filesystem, start simics with -fast flag instead of -stall flag. This would be much faster if you are only modifying some settings on the simulated machine. Best, Onur On Jan 11, 2013, at 11:18 PM, Diana Guttman <[email protected]<mailto:[email protected]>> wrote: Hi Mahmood, Thanks for your response. My command is: ./simics -stall /home/mdl/benchmarks/cloudsuite/workloads/nutch/simics/phase_000.config I think I know which errors you mean, but I have fixed those. So the only output I see is this: ######## Checking out a license... done: academic license. +----------------+ Copyright 1998-2007 by Virtutech, All Rights Reserved | Virtutech | Version: Simics 3.0.31 | Simics | Build: 1406 Host: amd64-linux +----------------+ www.simics.com<http://www.simics.com/> "Virtutech" and "Simics" are trademarks of Virtutech AB Use of this software is subject to appropriate license. Type 'copyright' for details on copyright. Type 'help help' for info on the on-line documentation. simics> c ######## For the other benchmarks, the windows pop up before the simics prompt, (and sometimes I see warnings like "xterm: cannot load font 6x10"). I am hoping this is not actually anything to worry about since I can still interact with the consoles through "server_con0.input" etc. Then the output shows up mixed with the simics output. But I don't understand why the console windows would come up for some but not others. Thanks, Diana On Thu, Jan 10, 2013 at 3:03 AM, Mahmood Naderan <[email protected]<mailto:[email protected]>> wrote: Hi Probably you get an error regarding checkpoint paths. You can paste your command and simics output. Regards, Mahmood ________________________________ From: Diana Guttman [[email protected]<mailto:[email protected]>] Sent: Wednesday, January 09, 2013 11:39 PM To: [email protected]<mailto:[email protected]> Subject: Viewing simics console window with cloudsuite images Hello, When running the released images with simics, I cannot see the console window for nutch or cassandra. Does anyone know what might be the problem? For the others, e.g. streaming, I do see console windows similar to the example from the tutorial slides. Thanks, Diana