When running QDI against any file, after the initial screen display, pressing 
any AID key causes message:
PIPIOS292E I/O error on CONSOLE; CSW X'000015D0 0020FFFF', CCW X'2AD31640 2080FF
FF'.
PIPMSG003I ... Issued from stage 4 of pipeline 1.
PIPMSG001I ... Running "fullscr".

Due diligence:

piplevel
PIPINX560I CMS/TSO Pipelines, 5654-030/5655-A17 level 110C000A.
PIPINX086I CMS/TSO Pipelines, 5654-030/5655-A17 1.0112 (Version.Release/Mod) -
Generated 24 Jul 2012 at 06:07:28
Source: Princeton Runtime Distribution

Msg 292E is documented as only being displayed for locally attached terminals, 
not for terminals connected not PVM,  VM/VCNA, or VM/VTAM.
This terminal runs from a Windows 7 laptop, running Bluezone terminal emulator, 
connected via TN3270/TN3270E using TN3270SSL from a z/OS system's VTAM USS 
display (i.e. VTAM encapsulation within TCP/IP, if I have the terms right).

When coming in purely via Telnet, FULLSCR causes no errors.

I 'noted' the "System Programmer Response" to the msg, but it offers no 
solution, nor any "User Response".

Thoughts/diagnostic tips?