Hi, If I were you I'd use one of the latest collectd builds, which has a fix [1] which seems to address issues ppl are having especially on Cisco hw.
Cheers [1] https://github.com/collectd/collectd/issues/131 On Sun, Jun 16, 2013 at 11:48:38PM +0800, Brendan Horan wrote: > Hi List, > > I am really enjoying collectd, thank you. > > I have two issues with collectd and SNMP plugin. > > I am using the following block to collect interface traffic stats : > <Data "std_traffic"> > Type "if_octets" > Table true > Instance "IF-MIB::ifDescr" > Values "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets" > </Data> > > This works fine for my Cisco kit, but all my Linux hosts never get any data > inside collectd. > That seems odd becase if I run the following "snmpwalk -v2c -c public > $HOSTNAME IF-MIB::ifInOctets" > > I get back the expected values. > > I don't understand what I am doing wrong. The above works for my Cisco kit, > works via snmpwalk. > > > The second issue I have and of much less importance is that on my Cisco > switch the above data block only brings back one VLAN. > On my Cisco Router all VLAN's are brought back. > > Unsure why my switch won't get all the VLANS, all physical switchports are > fine. > > Can someone give me a hand ? > > Thanks > Brendan > > _______________________________________________ > collectd mailing list > collectd@verplant.org > http://mailman.verplant.org/listinfo/collectd _______________________________________________ collectd mailing list collectd@verplant.org http://mailman.verplant.org/listinfo/collectd