henry3260 opened a new pull request, #76393:
URL: https://github.com/apache/airflow/pull/76393
`KubernetesPodOperator` waited out the full `startup_timeout` when an init
container's image could not be pulled.
`detect_pod_terminate_early_issues` scanned only
`status.container_statuses`. While init containers run, the main container
reports `PodInitializing`, which matches neither `FATAL_STATES` nor
`TRANSIENT_STATES`, so the detector returned `None` and the caller kept
polling. A typo in an init container image therefore cost the default 120s
instead of failing immediately.
The detector now scans `init_container_statuses` too, init containers first,
so a fatal init container image is reported ahead of the main container's
`PodInitializing`. This reaches all three callers: `await_pod_start`,
`await_pod_completion`, and the re-defer guard in `trigger_reentry`.
The error also names the stuck container now:
```
Image for container 'init' cannot be pulled, unable to start:
ImagePullBackOff
Back-off pulling image "nonexistent:latest"
```
Previously neither the raised error nor `_read_pod_container_states`
identified the container, and that log omits init containers entirely and runs
behind the non-default `log_events_on_failure`.
Builds on #65490, which introduced the transient-pattern allowlist this
reuses.
### Notes for reviewers
Two things the Gen-AI review checklist flags, both deliberate:
- **Two existing tests were modified.**
`test_start_pod_raises_fast_error_on_image_error` and its synchronous
counterpart changed because the error text now names the container. That is the
behaviour change itself, not an accommodation of a regression.
- **One added case passes without this branch.** The `main_container` half
of the `("InvalidImageName", '... "timeout-worker:Bad Tag"')` row is a
deliberate behaviour test. It pins the refactor to a single fatal/transient
condition, which is otherwise unguarded: mutating that condition so the fatal
branch also consults the message fails exactly those two cases and nothing
else. The `init_container` half does fail without the branch.
### Known related gap, not addressed here
The transient check matches the whole kubelet message, so a genuinely
missing image whose name happens to contain a transient pattern (for example
`timeout-worker`, which contains `timeout`) is still treated as transient and
waits out `startup_timeout`. That predates this change and has the same
user-visible symptom through a different trigger.
---
##### Was generative AI tooling used to co-author this PR?
- [X] Yes — Claude Code (Opus 5, 1M context)
Generated-by: Claude Code (Opus 5, 1M context) following [the
guidelines](https://github.com/apache/airflow/blob/main/contributing-docs/05_pull_requests.rst#gen-ai-assisted-contributions)
🤖 Generated with [Claude Code](https://claude.com/claude-code)
--