github-actions[bot] commented on code in PR #68786:
URL: https://github.com/apache/doris/pull/68786#discussion_r4236836034
##########
be/src/format/orc/vorc_reader.h:
##########
@@ -654,6 +654,18 @@ class OrcReader : public TableFormatReader, public
RowPositionProvider {
continue;
}
}
+ if (data->hasNulls && !data->notNull[i]) {
+ continue;
+ }
+ // Check the UTC epoch before packing: ORC permits years outside
Doris's 0001-9999 range.
+ static constexpr int64_t MIN_SECONDS = -62135596800LL;
Review Comment:
[P2] Accept UTC year zero in V1 ORC TIMESTAMPTZ scans. The new `MIN_SECONDS`
is 0001-01-01T00:00:00Z, but Doris and the V2 ORC reader accept
0000-01-01T00:00:00Z (`-62167219200`). With `enable_file_scanner_v2=false`, an
Iceberg ORC `TIMESTAMP_INSTANT` in that interval reaches this V1 decoder and
returns `DataQualityError` instead of a row. Use the Doris year-zero lower
epoch and cover this boundary in V1.
--