https://issues.apache.org/jira/browse/NIFI-846?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Joseph Witt updated NIFI-846:
-----------------------------
    Fix Version/s: 0.3.0

> MonitorActivity not setting start of evaluation period correctly
> ----------------------------------------------------------------
>
>                 Key: NIFI-846
>                 URL: https://issues.apache.org/jira/browse/NIFI-846
>             Project: Apache NiFi
>          Issue Type: Bug
>    Affects Versions: 0.2.1
>            Reporter: Brandon DeVries
>            Priority: Minor
>             Fix For: 0.3.0
>
>
> MonitorActivity uses a "latestSuccessTransfer" variable to determine 
> inactivity.  This is set when the processor is first instantiated, and then 
> on successful receipt of a FlowFile.  If NiFi takes longer to start up than 
> the configured threshold to start up, MonitorActivity can emit spurious 
> alerts.  Additionally, if the processor is stopped and then restarted after a 
> period greater than its threshold, if it doesn't get a FlowFile on its first 
> run of OnTrigger, it can emit a spurious alert as well. 
> A possible solution would be to add an @OnScheduled method that does:
> {code}
> latestSuccessTransfer.set(now);
> {code}
> This will essentially reset the evaluation period whenever the processor is 
> scheduled to run.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)