Sarthak-Pandey opened a new pull request, #20843: URL: https://github.com/apache/nuttx/pull/20843
## Summary TIM10 and TIM11 do not physically exist on the STM32H7 hardware family and were originally left over from copying timer drivers from STM32F7. References in `stm32_tickless.c` and `stm32_capture.c` pointed to non-existent base addresses (`STM32_TIM10_BASE`, `STM32_TIM11_BASE`) and undefined interrupt vectors (`STM32_IRQ_TIM10`, `STM32_IRQ_TIM11`). This PR cleans up the non-existent TIM10 and TIM11 configurations, switch cases, and private driver structures from STM32H7. Note that `TIM9` is preserved as it is valid and supported on the newer STM32H7RS variant. Fixes #11596 ## Impact - **Hardware/Architecture**: STM32H7 - **Users**: Prevents compilation failures and invalid configurations when selecting timers on STM32H7 platforms. - **Compatibility**: No breaking changes; removes dead code for peripherals that do not exist in silicon. ## Testing - Verified that `STM32_TIM10_BASE` and `STM32_TIM11_BASE` have no definitions in any STM32H7 hardware memory maps. - Verified that `stm32_tickless.c` and `stm32_capture.c` switch statements cleanly route valid timers (TIM1-TIM9, TIM12-TIM17). -- This is an automated message from the Apache Git Service. To respond to the message, please log on to GitHub and use the URL above to go to the specific comment. To unsubscribe, e-mail: [email protected] For queries about this service, please contact Infrastructure at: [email protected]