DanielLeens commented on PR #11912:
URL: https://github.com/apache/seatunnel/pull/11912#issuecomment-6646277945

   Thanks @SEZ9. I checked the current source for F6: 
SchemaEvolutionSinkFlow.coordinate (common Flink schema package, lines 40-72) 
is the entry that selects the new coordinated applier/broadcast path; 
FlinkSink:103-113 checks the writer capability, and the Flink writer refresh 
path also checks it. A repository search found no Zeta or Spark consumer of 
SupportCoordinatedSchemaEvolutionSink on this head. Thus the new coordinated 
execution path is currently Flink-specific; that does not establish coordinated 
support on the other engines. Please state that scope in the SPI Javadoc as you 
suggested. The actual merge conflict remains a separate blocker: resolve it 
against dev while preserving the lazy applier creation, physical-table 
ambiguity rejection and these contracts, then push the resulting head for one 
complete re-review. The source findings already resolved on this head should 
not be reopened merely because a rebase is pending.
   
   This is an unchanged-head discussion reply, not another complete source 
review. Daniel has READ permission; technical approval and GitHub's effective 
maintainer gate are separate.


-- 