Hi,

I'm wondering why adding alternate conformations to ligands (i.e. non
amino acid residues) restricts the occupancy ratio to 50:50. I
understand that ligands don't have rotamers (at least not ones that
coot would know about) so I can't pick rotamers.... but I'd like to be
able to specify the new occupancy with a little slide bar similarly to
amino acid residues.

Having non-1.0 occupancies complicate things further: I have a ligand
with a bromine atom that has partly fallen off at the synchrotron and
I refined it with occupancy = 0.5 (1.0 for all other atoms). When I
split this residue coot sets the occupancies to 0.5 for every atom,
except for the first half of the Br which will have 0.0. Again, I
understand the logic behind this... but wouldn't it be nicer to have
0.25 for both halves of the Br so that it adds up to the original 0.5?

RSR and regularize zone are also problematic for ligands in alternate
conformations: unless I click on atoms that are part of the split
region, RSR and regularize make the ligand explode.

JED

Reply via email to