On 11/03/14 07:14, Michael Engel wrote:
I can't reproduce the results I get by using find waters from within coot when 
running findwaters on the command line on the same pdb/mtz. I have double 
checked all the command line switches are the same and compared the output in 
the log files. Nothing obviously different but I am getting nearly 3x as many 
waters when running findwaters externally compared to starting it from the GUI, 
so as if the sigma was on a different scale.

So, do the first 1/3 of the waters from findwaters match those from the GUI? Does coot and findwaters report the same "density cut-off"?

And the other 2/3 are in smaller map peaks?

Although the water to protein distance limits are reported to be same, I 
couldn't find the command line switch to change them from their default values.



Right you are.  There isn't an option to change this.  I'll add it.

Cheers,

Paul.

Reply via email to