As a follow-up to this message,

set_display_lists_for_maps(0) in .coot.py does not work

but

(set-display-lists-for-maps 0) in .coot does work.

Is there some nasty little insect at work here?

Regards,

Pedro


Às 10:09 de 15/05/2020, Pedro Matias escreveu:
> Hi Paul,
>
> Sorry for insisting, but I can't get the set_display_lists_for_maps(0)
> to work on my $HOME/.coot.py preferences file. COOT starts in mono by
> default and this command is ignored. It only works after I enter stereo
> mode, input through the scripting window.  Also, it does not seem to be
> saved in the 0-coot-state files so if I resume a previous COOT session I
> have the same problem. Am I doing something wrong? Is there a workaround
> for this issue?
>
> BTW, the stereo on COOT 0.9 looks great - I guest that the different
> approach makes a big improvement.
>
> Best,
>
> Pedro
>
>
> Às 16:23 de 12/05/2020, Paul Emsley escreveu:
>> On 12/05/2020 14:42, Pedro Matias wrote:
>>> Hi,
>>
>> Hi.
>>
>>
>>> Is there a way to control stereo separation / depth in the new COOT? The
>>> picture is excessively deep in comparison with the previous version.
>>
>> What you are mostly seeing, I think, is that the transformation
>> between the eyes is no longer a rotation and is now a shear. Which
>> means that now we don't get part of the map showing up in the left eye
>> but not the right (or vice versa).
>>
>> Anyway, yes there is and it's documented in Section 3.4.1
>>
>> set_hardware_stereo_angle_factor(0.5) # for the Python fans
>>
>>
>>> BTW, the issue with set-display-lists-for-maps in stereo is still
>>> present in the COOT version distributed with CCP4 7.1.
>>>
>> It might be a while before I am sitting at a stereo display so that I
>> can address that. It's not top priority as there is a reasonable
>> work-around.
>>
>>
>> Paul.
>>
-- 

Industry and Medicine Applied Crystallography
Macromolecular Crystallography Unit
___________________________________
Phones : (351-21) 446-9100 Ext. 1669
         (351-21) 446-9669 (direct)
 Fax   : (351-21) 441-1277 or 443-3644

email : mat...@itqb.unl.pt

http://www.itqb.unl.pt/research/biological-chemistry/industry-and-medicine-applied-crystallography
http://www.itqb.unl.pt/labs/macromolecular-crystallography-unit

Mailing address :
Instituto de Tecnologia Quimica e Biologica António Xavier
Universidade Nova de Lisboa
Av. da República
2780-157 Oeiras
PORTUGAL

ITQB NOVA, a great choice for your PhD
https://youtu.be/de6j-aaTWNQ

Master Programme in Biochemistry for Health
https://youtu.be/UKstDCFjYI8

########################################################################

To unsubscribe from the COOT list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=COOT&A=1

This message was issued to members of www.jiscmail.ac.uk/COOT, a mailing list 
hosted by www.jiscmail.ac.uk, terms & conditions are available at 
https://www.jiscmail.ac.uk/policyandsecurity/

Reply via email to