https://issues.apache.org/jira/browse/HADOOP-4724?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=12651195#action_12651195
]
Hairong Kuang commented on HADOOP-4724:
---------------------------------------
> What property names to use?
Should we have one property per kind of ipc client? Something like
datanode.connect.timeout, tasktracker.connect.timeout,
dfsclient.connect.timeout...
> What are reasonable defaults for production systems?
I am thinking to start with a large number like 1 hour or 1 day. It is at least
backwards compatible.
> TaskTracker, DataNode, and SecondaryNameNode should timeout on waiting for
> its server to be up
> ----------------------------------------------------------------------------------------------
>
> Key: HADOOP-4724
> URL: https://issues.apache.org/jira/browse/HADOOP-4724
> Project: Hadoop Core
> Issue Type: Bug
> Reporter: Hairong Kuang
> Fix For: 0.20.0
>
>
> TaskTracker, DataNode, and SecondaryNameNode currently wait forever if its
> server is not up. They should be designed to take a configuration parameter
> that tells them when to give up, and a default value of many minutes/hours or
> more to deal with basic choreography issues in a cluster. Test clusters can
> be set up to fail sooner rather than later.
--
This message is automatically generated by JIRA.
-