A generator will sometimes lose the small amount of residual magnetism
it needs to start up. You produce a magnetic field by temporarily
connecting a DC source to the armature - this will remain strong enough
for many months or years to enable start-up.

Disconnect the ARMATURE wire from the regulator. Turn on the master
switch and TOUCH the disconnected lead to the BATT terminal on the
regulator, which should now have 12 volts on it. There will most likely
be a spark. Turn off the master and reconnect the armature lead. If the
generator does not produce a charge, the problem most likely resides in
the wiring or regulator, if the generator was tested by the rebuilder.

David
N6359V