https://issues.apache.org/jira/browse/CXF-1217?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel#action_12544949
]
willem Jiang commented on CXF-1217:
-----------------------------------
Hi Gary,
Thank you for tracing this issue.
I just committed the code which fixed the systest errors when turn off the
DontClosePort flag by setting the keep alive property and AllowChunking to be
false.
Just two quick question , I did not find the code in the HTTPConduit which set
the keepalive check interval. Can you point me out ?
Why can I get the test pass by waiting for a few second after the bus shutdown
? I do not think it is relate to the HTTPConduit retransmission mechanism.
> Address in use errors from attempt to repeatedly start and stop services
> ------------------------------------------------------------------------
>
> Key: CXF-1217
> URL: https://issues.apache.org/jira/browse/CXF-1217
> Project: CXF
> Issue Type: Bug
> Components: Transports
> Affects Versions: 2.1
> Environment: Any
> Reporter: Benson Margulies
> Assignee: willem Jiang
> Attachments: busShutdownTest.patch.txt, jetty6.1.6.patch
>
>
> Edit org.apache.cxf.javascript.JsHttpRequestTest to take out the
> @org.junit.Ignore from the test case that has one, and run from eclipse.
> Watch the logging traffic. Observe:
> WARNING: failed [EMAIL PROTECTED]
> java.net.BindException: Address already in use: bind
> at sun.nio.ch.Net.bind(Native Method)
> which eventually, as far as I can tell, turns into:
> INFO: doOpen POST http://localhost:8808/Greeter false
> Nov 18, 2007 10:07:08 PM org.apache.cxf.javascript.JsXMLHttpRequest
> communicate
> SEVERE: IO error reading response
> java.io.FileNotFoundException: http://localhost:8808/Greeter
> On the other hand, all is well in Eclipse.
> I will probably commit a workaround to this soon, so it would be good to move
> this muddle to its own test case.
--
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.