44100 Hz audio plays slightly fast on the DM365.
This is because the tlv320aic3x driver is calculating
invalid PLL parameters for the WCLK.  The parameters
it calculates are:

pll_p = 1, pll_r = 1, pll_j = 3, pll_d = 3450

According to the codec datasheet, the value of J
should be greater than 3.  The datasheet is correct.
The WCLK signal is unstable, bouncing between 44200 and 44500 Hz.

I recalculated the parameters by hand, setting P to 2
and got the following values:

pll_p = 2, pll_r = 1, pll_j = 6, pll_d = 6901

These values gave a clean 44100 WCLK.