Your message dated Sun, 28 Oct 2018 16:22:22 -0300 with message-id <[email protected]> and subject line Fixed upstream has caused the Debian Bug report #717531, regarding /sbin/shutdown: shutdown -P sets INIT_HALT to POWERDOWN instead of POWEROFF to be marked as done.
This means that you claim that the problem has been dealt with. If this is not the case it is now your responsibility to reopen the Bug report if necessary, and/or fix the problem forthwith. (NB: If you are a system administrator and have no idea what this message is talking about, this may indicate a serious mail system misconfiguration somewhere. Please contact [email protected] immediately.) -- 717531: https://bugs.debian.org/cgi-bin/bugreport.cgi?bug=717531 Debian Bug Tracking System Contact [email protected] with problems
--- Begin Message ---Package: sysvinit Version: 2.88dsf-43 Severity: normal File: /sbin/shutdown Hi, According to the shutdown(8), calling shutdown with the -P argument should set the INIT_HALT variable to POWEROFF. For some reasons, this is not the case and INIT_HALT is set to POWEROFF. HALT OR POWEROFF The -H option just sets the init environment variable INIT_HALT to HALT, and the -P option just sets that variable to POWEROFF. The shutdown script that calls halt(8) as the last thing in the shut‐ down sequence should check these environment variables and call halt(8) with the right options for these options to actually have any effect. Debian 3.1 (sarge) supports this. Cheers Laurent Bigonville -- System Information: Debian Release: jessie/sid APT prefers unstable APT policy: (500, 'unstable'), (1, 'experimental') Architecture: amd64 (x86_64) Foreign Architectures: i386 Kernel: Linux 3.10-1-amd64 (SMP w/8 CPU cores) Locale: LANG=fr_BE.utf8, LC_CTYPE=fr_BE.UTF-8 (charmap=UTF-8) Shell: /bin/sh linked to /bin/dash Versions of packages sysvinit depends on: ii debianutils 4.3.4 ii initscripts 2.88dsf-43 ii libc6 2.17-7 ii libselinux1 2.1.13-2 ii libsepol1 2.1.9-2 ii sysv-rc 2.88dsf-43 ii sysvinit-utils 2.88dsf-43 sysvinit recommends no packages. sysvinit suggests no packages. -- no debconf information
--- End Message ---
--- Begin Message ---This issue has been corrected upstream and INIT_HALT is now set to "POWEROFF" as described in the manual page. The fix will appear in sysvinit-2.92. - Jesse (upstream dev)
--- End Message ---