Hi,

this also breaks apcupsd when connecting a UPS through a USB-serial converter. It took some time to find this out, so I am not very amused.

This behaviour is not okay because modem-manager is installed by default and there is no simple standardised way for other applications to stop it from interfering with a particular device.

Because the status lines are changed when opening and closing a device, some boards like Arduino-based 3D printer controls even reset because of modem-manager testing them!

We need to find some solution so that this autoprobing is not active by default (only enabled after user interaction), since it is impossible to change every single control software using a serial port.

Thanks

Max Gaukler


--
To UNSUBSCRIBE, email to debian-bugs-dist-requ...@lists.debian.org
with a subject of "unsubscribe". Trouble? Contact listmas...@lists.debian.org