Control: found -1 44~beta-1 On Mon, 20 Feb 2023 at 09:54:38 +0000, Simon McVittie wrote: > I think this is another way to describe the upstream bug that > was fixed by mutter 43.3-3.
I think this also needs fixing in 44~beta-1 (I haven't confirmed this myself, I'm staying on GNOME 43 for now to try to get Debian 12 into shape). A simple reproducer: - have an X11 window (I used `git gui`) - have a Wayland window (I used gnome-terminal) - focus the X11 window - go to the Overview with the Windows key - click the Wayland window - good result: focus moves to the Wayland window - bad result: Wayland window stays unfocused (dim titlebar, etc.) The fix is https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/2841 upstream. Jeremy or other people working on GNOME 44 betas: please could you grab that change next time you update mutter? Thanks, smcv