Hi,

I should have waited a bit longer before filing this bug report:

The charge is not reported as a constant but seems to go down in 25% portions. 
Starting with a fully charged battery powersave will show 100% until the acpi 
charge goes down to 94% . Powersave will then display 75%. I don't know yet 
how this will continue.

Please, accept my apologies for not properly checking the correctness of my 
original report, especially in the light of giving it such a high severity. 
Sorry!!!

On Friday 08 December 2006 19:05, you wrote:
> powersaved gets the information from hal. What does
> "lshal | grep battery" say?

Here's the output:

~$ lshal | grep battery
  battery.remaining_time = 10800  (0x2a30)  (int)
  battery.charge_level.percentage = 75  (0x4b)  (int)
  battery.charge_level.rate = 1  (0x1)  (int)
  battery.charge_level.last_full = 4  (0x4)  (int)
  battery.charge_level.current = 3  (0x3)  (int)
  battery.voltage.current = 1  (0x1)  (int)
  battery.reporting.rate = 1596  (0x63c)  (int)
  battery.reporting.current = 3696  (0xe70)  (int)
  battery.charge_level.capacity_state = 'ok'  (string)
  battery.rechargeable.is_discharging = true  (bool)
  battery.rechargeable.is_charging = false  (bool)
  battery.is_rechargeable = true  (bool)
  battery.charge_level.unit = 'mWh'  (string)
  battery.charge_level.granularity_2 = 473  (0x1d9)  (int)
  battery.charge_level.granularity_1 = 473  (0x1d9)  (int)
  battery.charge_level.low = 1953  (0x7a1)  (int)
  battery.charge_level.warning = 4440  (0x1158)  (int)
  battery.charge_level.design = 65120  (0xfe60)  (int)
  battery.voltage.design = 14800  (0x39d0)  (int)
  battery.voltage.unit = 'mV'  (string)
  battery.reporting.granularity_2 = 32  (0x20)  (int)
  battery.reporting.granularity_1 = 32  (0x20)  (int)
  battery.reporting.low = 132  (0x84)  (int)
  battery.reporting.warning = 300  (0x12c)  (int)
  battery.reporting.design = 4400  (0x1130)  (int)
  battery.reporting.last_full = 4206  (0x106e)  (int)
  battery.reporting.unit = 'mAh'  (string)
  battery.technology = 'lithium-ion'  (string)
  battery.reporting.technology = 'LION'  (string)
  battery.serial = '12025'  (string)
  battery.model = 'ZL01'  (string)
  battery.vendor = 'SANYO'  (string)
  battery.present = true  (bool)
  info.capabilities = {'battery'} (string list)
  info.category = 'battery'  (string)
  battery.type = 'primary'  (string)
  linux.acpi_path = '/proc/acpi/battery/BAT1'  (string)
  battery.present = false  (bool)
  info.capabilities = {'battery'} (string list)
  info.category = 'battery'  (string)
  battery.type = 'primary'  (string)
  linux.acpi_path = '/proc/acpi/battery/BAT2'  (string)

Kind regards,

Felix








-- 
To UNSUBSCRIBE, email to [EMAIL PROTECTED]
with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]

Reply via email to