Package: torsmo
Version: 0.18-3
Severity: important
torsmo, as of 0.18-3, does not update the sensors correctly.
With the lines in my .torsmorc:
Temperatures: CPU: ${i2c temp 1}�C - MB: ${i2c temp 2}�C - Remote:
${i2c temp 3}�C
Fans: CPU: ${i2c fan 1} RPM Rear: ${i2c fan 4} RPM
Ther numbers do not update when the temperatures or fan RPMs change.
The temperatues and RPMs update with other packages, such as gkrellm.
strace on torsmo gives me this:
~$ strace 2>&1 torsmo | grep fan
open("/sys/bus/i2c/devices/1-002e/fan1_input", O_RDONLY) = 8
open("/sys/bus/i2c/devices/1-002e/fan1_div", O_RDONLY) = -1 ENOENT (No
such file or directory)
open("/sys/bus/i2c/devices/1-002e/fan4_input", O_RDONLY) = 9
open("/sys/bus/i2c/devices/1-002e/fan4_div", O_RDONLY) = -1 ENOENT (No
such file or directory)
watch(1)ing the file shows it being updated, but torsmo doesn't update
the line in its display. :-(
--
Willie Gnarlson