Hello all,

Background paragraph:
I've recently acquired a second hand HP ScanJet 5300c to replace my now
broken ScanJet 6100c, and first of all ran into the same problems as bug
#474706. After some playing around, I managed to work around that by
adding both disable options to my avision.conf file. Bizarrely, this
only worked the second time I tried it, so when I have a little more
time (probably tomorrow) I'll try reproducing the problem, and if I can
I'll update that report.

However, starting xsane takes a huge amount of time. scanimage and
xscanimage do not suffer the same problem. It looks like the issue is to
do with the avision backend - I've attached a copy of my avision.conf
and the debug log from running "SANE_DEBUG_AVISION=255 xsane" to
illustrate the point.

The behaviour is that xsane briefly displays the scanning for devices
window, then removes it and partially draws the histogram window. Then,
a long delay occurs. Eventually, the preview window is drawn and another
delay of about the same amount of time occurs. The delay is the order of
a few minutes, probably about 3-4 minutes each stage (sorry, I've not
timed it exactly).

I'll try to investigate further when I get time, and will update this
report if I find anything that seems useful. Similarly, if there's
any particular information you'd like from me, just let me know and I'll
get it sorted out as soon as possible.

All the best,
- -Dave.

- -- System Information:
Debian Release: lenny/sid
  APT prefers unstable
  APT policy: (500, 'unstable'), (500, 'testing')
Architecture: amd64 (x86_64)

Kernel: Linux 2.6.25.4 (SMP w/2 CPU cores)
Locale: LANG=en_GB, LC_CTYPE=en_GB (charmap=ISO-8859-1)
Shell: /bin/sh linked to /bin/bash

Versions of packages libsane depends on:
ii  adduser                      3.108       add and remove users and groups
ii  libavahi-client3             0.6.22-3    Avahi client library
ii  libavahi-common3             0.6.22-3    Avahi common library
ii  libc6                        2.7-12      GNU C Library: Shared libraries
ii  libexif12                    0.6.16-2.1  library to parse EXIF files
ii  libgphoto2-2                 2.4.0-9     gphoto2 digital camera library
ii  libgphoto2-port0             2.4.0-9     gphoto2 digital camera port librar
ii  libieee1284-3                0.2.11-4    cross-platform library for paralle
ii  libjpeg62                    6b-14       The Independent JPEG Group's JPEG 
ii  libsane-extras               1.0.19.7    API library for scanners -- extra 
ii  libtiff4                     3.8.2-8     Tag Image File Format (TIFF) libra
ii  libusb-0.1-4                 2:0.1.12-11 userspace USB programming library
ii  makedev                      2.3.1-88    creates device files in /dev
ii  udev                         0.114-2     /dev/ and hotplug management daemo

Versions of packages libsane recommends:
ii  avahi-daemon                  0.6.22-3   Avahi mDNS/DNS-SD daemon
ii  sane-utils                    1.0.19-11  API library for scanners -- utilit

- -- debconf-show failed

-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.4.9 (GNU/Linux)
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=P1Hv
-----END PGP SIGNATURE-----
# This are the possible options. Normally any scanner
# should work just fine without them - and they are only
# needed for test and debugging. So if you experience problems
# and you solve them with enabling options here, please notify
# the SANE/Avision maintainer: Rene Rebe <[EMAIL PROTECTED]>

option disable-gamma-table
option disable-calibration
#option force-a4

#scsi AVISION
#scsi FCPA
#scsi MINOLTA
#scsi MITSBISH MCA-S600C
#scsi MITSBISH MCA-SS600
#scsi HP
#scsi hp

#scsi /dev/scanner
#usb libusb:002:003
#usb 0x03f0 0x0701

Attachment: xsane.log.gz