On Tue, Dec 23, 2008 at 07:57:00PM +0100, Stefan Bühler wrote:
> The problem is that check_timeout is reset after the first battery got
> updated, so the values for the second battery are never read.
> 
> This results in status->value == NULL, and strncmp segfaults.
> 
> The solution is to update check_timeout after all battery values are updated.

excellent, thanks
-- 