Package: apcupsd Version: 3.10.18-1 Severity: minor apcaccess status reports wrong line voltage for my UPS. An endianness issue perhaps? It says 'LINEV : 59210.4 Volts'. Note that 59210.4 / 256 = 231.291 which is probably what it should report.
[63705] [14:06] [EMAIL PROTECTED] ~ % apcaccess status APC : 001,038,0937 DATE : Wed Sep 28 14:06:24 EEST 2005 HOSTNAME : apyykko.pp.oamk.fi RELEASE : 3.10.18 VERSION : 3.10.18 (21 July 2005) debian UPSNAME : APC CABLE : USB Cable MODEL : Back-UPS BR 800 UPSMODE : Stand Alone STARTTIME: Sat Sep 17 16:40:11 EEST 2005 STATUS : ONLINE LINEV : 59210.4 Volts LOADPCT : 20.0 Percent Load Capacity BCHARGE : 100.0 Percent TIMELEFT : 40.1 Minutes MBATTCHG : 5 Percent MINTIMEL : 3 Minutes MAXTIME : 0 Seconds OUTPUTV : 230.0 Volts DWAKE : 000 Seconds DSHUTD : 000 Seconds LOTRANS : 194.0 Volts HITRANS : 264.0 Volts ITEMP : 29.2 C Internal ALARMDEL : Always BATTV : 27.8 Volts LINEFREQ : 50.0 Hz NUMXFERS : 0 TONBATT : 0 seconds CUMONBATT: 0 seconds XOFFBATT : N/A SELFTEST : NO STATFLAG : 0x02000008 Status Flag SERIALNO : QB0420246146 BATTDATE : 2001-09-25 NOMBATTV : 24.0 FIRMWARE : .o2 .I USB FW:o2 APCMODEL : Back-UPS BR 800 END APC : Wed Sep 28 14:06:33 EEST 2005 -- System Information: Debian Release: testing/unstable APT prefers unstable APT policy: (500, 'unstable'), (500, 'testing'), (500, 'stable') Architecture: amd64 (x86_64) Shell: /bin/sh linked to /bin/bash Kernel: Linux 2.6.13 Locale: LANG=C, LC_CTYPE=C (charmap=ANSI_X3.4-1968) Versions of packages apcupsd depends on: ii libc6 2.3.5-6 GNU C Library: Shared libraries an ii libncurses5 5.4-9 Shared libraries for terminal hand ii libsnmp4.2 4.2.5-5 NET SNMP (Simple Network Managemen ii libssl0.9.7 0.9.7g-2 SSL shared libraries ii libwrap0 7.6.dbs-8 Wietse Venema's TCP wrappers libra apcupsd recommends no packages. -- no debconf information -- To UNSUBSCRIBE, email to [EMAIL PROTECTED] with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]