...I should also mention, dropping to OBP and typing "led-off" then "go" should extinguish the light and get you back to the OS-- that's a simpler workaround ;)
E On Tue, 2 Nov 2004 10:55:11 -0700, Eric Brower <[EMAIL PROTECTED]> wrote: > On the E250, the "General Error" LED on the front status panel is > plumbed to the auxio power LED bit (logical OR, if I recall > correctly). If it bothers you, I'd be happy to provide a patch to > you. Alternatively, I have a rough SUNW,envctrtltwo environmental > monitoring driver for the E250 I'd be happy to provide-- I've been > meaning to convert it to the in-kernel I2C subsystem and add > multi-master support but I've just not gotten around to it. Let me > know. > > E > > > > > On Mon, 1 Nov 2004 22:14:48 -0500, Huston <[EMAIL PROTECTED]> wrote: > > > > I have an E250 server. Every time it kicks in the hard drives. I get a > > maintenance light. If I don't boot into the OS, I don't get the light. I > > don't remember it doing this with Solaris. Is there something I need to > > change configuration wise or did the problem just seem to coincide the > > change of OS? The only thing I notice is the cdrom seems to show activity > > longer.. Any suggestions would be appreciated..... > > > -- > E > -- E