Jon Dowland wrote:

> On Sat, Dec 11, 2004 at 11:48:05PM +0000, ognjen Bezanov wrote:
>> After Setting up my RAID5 Array (4x 40gb drives) i got 120GB free space
>> and everything seemed ok, then after restart i was told that i had a
>> failure on a non-existant drive and the array rebuilt itself, not a big
>> deal in itself.
> 
> Forgive me if I'm wrong, but surely you shouldn't have 120GB on your
> RAID5 device. That means there's no redundancy / fail safe.

No, there is redundancy - he can lose a drive and not lose any data.

What there isn't is a hot spare. This is beneficial, but not required.

Adam


-- 
To UNSUBSCRIBE, email to [EMAIL PROTECTED] 
with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]