I need to connect two terminals to my Linux box, I have in my inittab
file:

s1:12345:respawn:/sbin/agetty 19200 ttyS0 vt100
s2:12345:respawn:/sbin/agetty 19200 ttyS1 vt100


The login prompt appears well in my terminals; but when I try to login I
can't do it.

Can someone help me?
#
# inittab       This file describes how the INIT process should set up
#               the system in a certain run-level.
#
# Version:      @(#)inittab             2.04    17/05/93        MvS
#                                       2.10    02/10/95        PV
#
# Author:       Miquel van Smoorenburg, <[EMAIL PROTECTED]>
# Modified by:  Patrick J. Volkerding, <[EMAIL PROTECTED]>
#
# Default runlevel.
id:3:initdefault:

# System initialization (runs when system boots).
si:S:sysinit:/etc/rc.d/rc.S

# Script to run when going single user (runlevel 1).
su:1S:wait:/etc/rc.d/rc.K

# Script to run when going multi user.
rc:23456:wait:/etc/rc.d/rc.M

# What to do at the "Three Finger Salute".
ca::ctrlaltdel:/sbin/shutdown -t5 -rfn now

# Runlevel 0 halts the system.
l0:0:wait:/etc/rc.d/rc.0

# Runlevel 6 reboots the system.
l6:6:wait:/etc/rc.d/rc.6

# What to do when power fails (shutdown to single user).
pf::powerfail:/sbin/shutdown -f +5 "THE POWER IS FAILING"

# If power is back before shutdown, cancel the running shutdown.
pg:0123456:powerokwait:/sbin/shutdown -c "THE POWER IS BACK"

# If power comes back in single user mode, return to multi user mode.
ps:S:powerokwait:/sbin/init 5

# The getties in multi user mode on consoles an serial lines.
#
# NOTE NOTE NOTE adjust this to your getty or you will not be
#                able to login !!
#
# Note: for 'agetty' you use linespeed, line.
# for 'getty_ps' you use line, linespeed and also use 'gettydefs'
c1:1235:respawn:/sbin/agetty 38400 tty1 linux
c2:1235:respawn:/sbin/agetty 38400 tty2 linux
c3:1235:respawn:/sbin/agetty 38400 tty3 linux
c4:1235:respawn:/sbin/agetty 38400 tty4 linux
c5:1235:respawn:/sbin/agetty 38400 tty5 linux
c6:12345:respawn:/sbin/agetty 38400 tty6 linux

# Serial lines
#s1:12345:respawn:/sbin/agetty 19200 ttyS0 vt100
#s2:12345:respawn:/sbin/agetty 19200 ttyS1 vt100

#------------------------------------------------
#                 ojo-provisional
#------------------------------------------------
#s2:456:respawn:/sbin/uugetty 9600 ttyS1 vt100
#------------------------------------------------


# Dialup lines
#d1:12345:respawn:/sbin/agetty -mt60 38400,19200,9600,2400,1200 ttyS0 vt100
#d2:12345:respawn:/sbin/agetty -mt60 38400,19200,9600,2400,1200 ttyS1 vt100

# Runlevel 4 used to be for an X-window only system, until we discovered
# that it throws init into a loop that keeps your load avg at least 1 all 
# the time. Thus, there is now one getty opened on tty6. Hopefully no one
# will notice. ;^)
# It might not be bad to have one text console anyway, in case something 
# happens to X.
x1:4:wait:/etc/rc.d/rc.4

# End of /etc/inittab