I have 2 machines(IBM servers). Both use bnx2 NIC driver but one is VERY
slow to boot thru kernel (2.3s vs 27s)

Config is:

auto bond508
allow-hotplug bond508

iface bond508 inet  static
    address 1.2.3.4/24
    slaves eth0.508 eth1.508
    bond-mode active-backup
    


on "fast" one it "just" works, NIC is initialized first, VLAN
interfaces are created, bond adds them and everything works

on "slow" one bond starts with no interfaces because ifup happens
before NIC driver settled (eth0/1 are not in the system), 

it looks like that

Apr 28 17:49:31 blade710 kernel: [   44.346366] bonding: Ethernet Channel 
Bonding Driver: v3.7.1 (April 27, 2011)
Apr 28 17:49:31 blade710 kernel: [   44.421839] bonding: bond508 is being 
created...
Apr 28 17:49:31 blade710 kernel: [   44.424930] bonding: bond508: Setting xmit 
hash policy to layer3+4 (1)
Apr 28 17:49:31 blade710 kernel: [   44.429511] bonding: bond508: option 
lacp_rate: mode dependency failed, not supported in mode active-backup(1)
Apr 28 17:49:31 blade710 kernel: [   44.435247] bonding: bond508: interface 
eth0.508 does not exist!
Apr 28 17:49:31 blade710 kernel: [   44.440974] bonding: bond508: interface 
eth1.508 does not exist!
Apr 28 17:49:31 blade710 kernel: [   44.444804] IPv6: ADDRCONF(NETDEV_UP): 
bond508: link is not ready

then NIC boots:

Apr 28 17:49:31 blade710 kernel: [   44.492469] bnx2 0000:10:00.0: firmware: 
direct-loading firmware bnx2/bnx2-mips-09-6.2.1b.fw
Apr 28 17:49:31 blade710 kernel: [   44.494198] bnx2 0000:10:00.0: firmware: 
direct-loading firmware bnx2/bnx2-rv2p-09-6.0.17.fw
Apr 28 17:49:31 blade710 kernel: [   44.494243] bnx2 0000:10:00.0: irq 74 for 
MSI/MSI-X
Apr 28 17:49:31 blade710 kernel: [   44.494251] bnx2 0000:10:00.0: irq 75 for 
MSI/MSI-X
Apr 28 17:49:31 blade710 kernel: [   44.494257] bnx2 0000:10:00.0: irq 76 for 
MSI/MSI-X
Apr 28 17:49:31 blade710 kernel: [   44.494263] bnx2 0000:10:00.0: irq 77 for 
MSI/MSI-X
Apr 28 17:49:31 blade710 kernel: [   44.494269] bnx2 0000:10:00.0: irq 78 for 
MSI/MSI-X
Apr 28 17:49:31 blade710 kernel: [   44.494275] bnx2 0000:10:00.0: irq 79 for 
MSI/MSI-X
Apr 28 17:49:31 blade710 kernel: [   44.494281] bnx2 0000:10:00.0: irq 80 for 
MSI/MSI-X
Apr 28 17:49:31 blade710 kernel: [   44.494286] bnx2 0000:10:00.0: irq 81 for 
MSI/MSI-X
Apr 28 17:49:31 blade710 kernel: [   44.494292] bnx2 0000:10:00.0: irq 82 for 
MSI/MSI-X
Apr 28 17:49:31 blade710 kernel: [   44.553877] bnx2 0000:10:00.0 eth0: using 
MSIX
Apr 28 17:49:31 blade710 kernel: [   44.553917] IPv6: ADDRCONF(NETDEV_UP): 
eth0: link is not ready
Apr 28 17:49:31 blade710 kernel: [   44.610343] bnx2 0000:10:00.0 eth0: NIC 
SerDes Link is Up, 1000 Mbps full duplex

I *can* make it work on boot if I define eth interfaces separately:


iface eth0.508 inet manual
    bond-master bond508
    bond-mode active-backup

but that is not exactly pretty solution... is there a way to force
bonding interfaces to get up only after required devices are up ?


-- 
Mariusz Gronczewski, Administrator

Efigence S. A.
ul. WoĊ‚oska 9a, 02-583 Warszawa
T: [+48] 22 380 13 13
F: [+48] 22 380 13 14
E: mariusz.gronczew...@efigence.com
<mailto:mariusz.gronczew...@efigence.com>

Reply via email to