I uninstalled 0.90.1-2 and reinstalled 0.90.1. It seems to be working okay.
I ran the program (0.90.1-2) but removed the --mbox parameter. It then gave me an error message about --max-ratio. I removed that one, and it then gave me an error about --max-space. I removed that one as well, and it was finally able to run. But there was an error in the report.txt file: 62376245.eml: lstat() failed. ERROR For now I am just going to keep running with 0.90.1 and see how it goes. The message I received on the clamav-announce mailing list about 0.90.1-2 stated, "Basically, this version corrects some build problems and incorrect linkage to cygclamav1.dll by clamd." Gary -------- Original Message -------- > From: "Mark Reimer" <[EMAIL PROTECTED]> > Sent: Tuesday, March 13, 2007 11:21 AM > To: declude.virus@declude.com > Subject: RE: [Declude.Virus] ClamAV 0.90.1-2 problems > > Gary, > I had the same problem after upgrading to 0.90.1-2. I had to go back to > 0.90-1. I was getting the same error code. After this upgrade if I go back > to 0.90.1-1 I get error code 40. I have not been able to figure out what is > going on. > > Mark Reimer > IT System Admin > American CareSource > 972-308-6887 > > -----Original Message----- > From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Nick > Hayer > Sent: Tuesday, March 13, 2007 8:01 AM > To: declude.virus@declude.com > Subject: Re: [Declude.Virus] ClamAV 0.90.1-2 problems > > Exit code of 2 means ClamAV had an error - Is clamd running? will > clamdscan.exe <file to be scanned> work? eg no parameters? > > -Nick > > Gary Steiner wrote: > > Ever since I upgraded to ClamAV 0.90.1-2 (the SOSDG windows port), I've > been unable to get it to work. The Declude log files show an error like > this: > > > > 03/12/2007 19:17:29.359 62376245 Vulnerability flags = 861 > > 03/12/2007 19:17:29.359 62376245 MIME file: [text/html][7bit; Length=429 > Checksum=38095] > > 03/12/2007 19:17:30.171 62376245 Virus scanner 1 reports exit code of 2 > > 03/12/2007 19:17:32.218 62376245 Virus scanner 1 reports exit code of 2 > > 03/12/2007 19:17:34.265 62376245 Virus scanner 1 reports exit code of 2 > > 03/12/2007 19:17:36.312 62376245 Virus scanner 1 reports exit code of 2 > > 03/12/2007 19:17:38.359 62376245 Virus scanner 1 reports exit code of 2 > > 03/12/2007 19:17:40.359 62376245 Could not find report file > c:\SmarterMail\Spool\proc\work\62376245.vir\report.txt. > > 03/12/2007 19:17:40.359 62376245 Error 2 in virus scanner 1. > > 03/12/2007 19:17:40.562 62376245 Virus scanner 2 reports exit code of 0 > > 03/12/2007 19:17:40.562 62376245 Scanned: Error in virus scanner. [MIME: 2 > 815] > > > > > > If I try to run it from the command line using the parameters from my > virus.cfg file, I get the following: > > > > C:\clamav-devel\bin\clamdscan.exe --quiet --mbox --max-ratio 0 --max-space > 1M -l report.txt 62376245.eml > > > > /cygdrive/c/clamav-devel/bin/clamdscan: unrecognized option `--mbox' > > ERROR: Unknown option passed. > > ERROR: Can't parse the command line > > > > > > Anyone else seeing anything like this? Did something change in 0.90 to > make these paramenters invalid? > > > > Thanks, > > > > Gary Steiner > > > > --- This E-mail came from the Declude.Virus mailing list. To unsubscribe, just send an E-mail to [EMAIL PROTECTED], and type "unsubscribe Declude.Virus". The archives can be found at http://www.mail-archive.com.