I uninstalled 0.90.1-2 and reinstalled 0.90.1.  It seems to be working okay.

I ran the program (0.90.1-2) but removed the --mbox parameter.  It then gave me 
an error message about --max-ratio.  I removed that one, and it then gave me an 
error about --max-space.  I removed that one as well, and it was finally able 
to run.  But there was an error in the report.txt file:

62376245.eml: lstat() failed. ERROR

For now I am just going to keep running with 0.90.1 and see how it goes.

The message I received on the clamav-announce mailing list about 0.90.1-2 
stated, "Basically, this version corrects some build problems and incorrect 
linkage to cygclamav1.dll by clamd."

Gary


-------- Original Message --------
> From: "Mark Reimer" <[EMAIL PROTECTED]>
> Sent: Tuesday, March 13, 2007 11:21 AM
> To: declude.virus@declude.com
> Subject: RE: [Declude.Virus] ClamAV 0.90.1-2 problems
> 
> Gary,
> I had the same problem after upgrading to 0.90.1-2. I had to go back to
> 0.90-1. I was getting the same error code. After this upgrade if I go back
> to 0.90.1-1 I get error code 40. I have not been able to figure out what is
> going on.
> 
> Mark Reimer
> IT System Admin
> American CareSource
> 972-308-6887
>  
> -----Original Message-----
> From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Nick
> Hayer
> Sent: Tuesday, March 13, 2007 8:01 AM
> To: declude.virus@declude.com
> Subject: Re: [Declude.Virus] ClamAV 0.90.1-2 problems
> 
> Exit code of 2 means ClamAV had an error - Is clamd running? will 
> clamdscan.exe <file to be scanned> work? eg no parameters?
> 
> -Nick
> 
> Gary Steiner wrote:
> > Ever since I upgraded to ClamAV 0.90.1-2 (the SOSDG windows port), I've
> been unable to get it to work.  The Declude log files show an error like
> this:
> >
> > 03/12/2007 19:17:29.359 62376245 Vulnerability flags = 861
> > 03/12/2007 19:17:29.359 62376245 MIME file: [text/html][7bit; Length=429
> Checksum=38095]
> > 03/12/2007 19:17:30.171 62376245 Virus scanner 1 reports exit code of 2
> > 03/12/2007 19:17:32.218 62376245 Virus scanner 1 reports exit code of 2
> > 03/12/2007 19:17:34.265 62376245 Virus scanner 1 reports exit code of 2
> > 03/12/2007 19:17:36.312 62376245 Virus scanner 1 reports exit code of 2
> > 03/12/2007 19:17:38.359 62376245 Virus scanner 1 reports exit code of 2
> > 03/12/2007 19:17:40.359 62376245 Could not find report file
> c:\SmarterMail\Spool\proc\work\62376245.vir\report.txt.
> > 03/12/2007 19:17:40.359 62376245 Error 2 in virus scanner 1.
> > 03/12/2007 19:17:40.562 62376245 Virus scanner 2 reports exit code of 0
> > 03/12/2007 19:17:40.562 62376245 Scanned: Error in virus scanner. [MIME: 2
> 815]
> >
> >
> > If I try to run it from the command line using the parameters from my
> virus.cfg file, I get the following:
> >
> > C:\clamav-devel\bin\clamdscan.exe --quiet --mbox --max-ratio 0 --max-space
> 1M -l report.txt 62376245.eml
> >
> > /cygdrive/c/clamav-devel/bin/clamdscan: unrecognized option `--mbox'
> > ERROR: Unknown option passed.
> > ERROR: Can't parse the command line
> >
> >
> > Anyone else seeing anything like this?  Did something change in 0.90 to
> make these paramenters invalid?
> >
> > Thanks,
> >
> > Gary Steiner
> >
> >







---
This E-mail came from the Declude.Virus mailing list.  To
unsubscribe, just send an E-mail to [EMAIL PROTECTED], and
type "unsubscribe Declude.Virus".    The archives can be found
at http://www.mail-archive.com.

Reply via email to