https://issues.apache.org/jira/browse/DERBY-2806?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Kristian Waagan closed DERBY-2806.
----------------------------------


> calling getByteLength on org.apache.derby.impl.jdbc.StoreStreamClob makes 
> BinaryStream, fetched before this call, unusable
> --------------------------------------------------------------------------------------------------------------------------
>
>                 Key: DERBY-2806
>                 URL: https://issues.apache.org/jira/browse/DERBY-2806
>             Project: Derby
>          Issue Type: Bug
>          Components: JDBC
>    Affects Versions: 10.2.2.0, 10.3.1.4
>            Reporter: Anurag Shekhar
>            Assignee: Kristian Waagan
>             Fix For: 10.3.1.4
>
>         Attachments: derby-2806-1a.diff, derby-2806-2a.diff, 
> derby-2806-2a.stat, derby-2806-3a-test_fix_and_cleanup.diff, Derby2806.java
>
>
> StoreStreamClob.getByteLength first resets the internal stream and then reads 
> the entire stream. Due to this any read on Stream obtained by 
> StoreStreamClob.getRawByteStream returns -1.
> StoreStreamClob is a read only InternalClob, so probably keeping the length 
> in a variable will be good idea.

-- 
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.

Reply via email to