** Description changed:

  Binary package hint: gnome-power-manager
  
  $ lsb_release -rd
  Description:  Ubuntu 8.10
  Release:      8.10
  -------------------------------------
  Power Manager 2.24.0
  -------------------------------------
  Hardware: IBM ThinkPad R40
  -------------------------------------
  I am using two batteries with the laptop - one internal and one additional 
that plugs into CD-ROM bay.
  While running on battery power the additional battery discharges first (it's 
OK) but when it reaches critical low level the power manager hibernates the 
computer (correct action on low battery, also ok) instead of switching to the 
second battery (here is the problem, very annoying).
  
  Also the time remaining is mostly correct while running on one battery
  (any one) but totally wrong when two of them installed. i.e. while
  running on the additional battery the time remaining indicator shows
  correct time for one battery but not overall time remaining. If the
  second battery removed time for the internal battery shown correctly,
  but if the second battery installed the remaining time shows some value
  that represents absolutely nothing.
  
  another issue, that if second battery installed before the main while
  running on AC adapter the additional battery is not recognized with
  power manager and therefore not charged.
+ 
+ :~$ gnome-power-bugreport.sh
+ Distro version:       DISTRIB_ID=Ubuntu
+ DISTRIB_RELEASE=8.10
+ DISTRIB_CODENAME=intrepid
+ DISTRIB_DESCRIPTION="Ubuntu 8.10"
+ Kernel version:       2.6.27-9-generic
+ g-p-m version:        2.24.0
+ HAL version:          0.5.11
+ System manufacturer:  missing
+ System version:       missing
+ System product:       missing
+ AC adapter present:   yes
+ Battery present:      yes
+ Laptop panel present: yes
+ CPU scaling present:  yes
+ Battery Information:
+   battery.charge_level.current = 18850  (0x49a2)  (int)
+   battery.charge_level.design = 34560  (0x8700)  (int)
+   battery.charge_level.last_full = 19180  (0x4aec)  (int)
+   battery.charge_level.percentage = 98  (0x62)  (int)
+   battery.charge_level.rate = 2881  (0xb41)  (int)
+   battery.is_rechargeable = true  (bool)
+   battery.model = 'IBM-02K6645'  (string)
+   battery.present = true  (bool)
+   battery.rechargeable.is_charging = true  (bool)
+   battery.rechargeable.is_discharging = false  (bool)
+   battery.remaining_time = 412  (0x19c)  (int)
+   battery.reporting.current = 18850  (0x49a2)  (int)
+   battery.reporting.design = 34560  (0x8700)  (int)
+   battery.reporting.last_full = 19180  (0x4aec)  (int)
+   battery.reporting.rate = 2881  (0xb41)  (int)
+   battery.reporting.technology = 'Li-ion'  (string)
+   battery.reporting.unit = 'mWh'  (string)
+   battery.serial = ' 1057'  (string)
+   battery.technology = 'lithium-ion'  (string)
+   battery.type = 'primary'  (string)
+   battery.vendor = 'SANYO'  (string)
+   battery.voltage.current = 12528  (0x30f0)  (int)
+   battery.voltage.design = 10800  (0x2a30)  (int)
+   battery.voltage.unit = 'mV'  (string)
+   battery.charge_level.current = 60000  (0xea60)  (int)
+   battery.charge_level.design = 63360  (0xf780)  (int)
+   battery.charge_level.last_full = 60090  (0xeaba)  (int)
+   battery.charge_level.percentage = 99  (0x63)  (int)
+   battery.charge_level.rate = 0  (0x0)  (int)
+   battery.is_rechargeable = true  (bool)
+   battery.model = 'IBM-02K7054'  (string)
+   battery.present = true  (bool)
+   battery.rechargeable.is_charging = false  (bool)
+   battery.rechargeable.is_discharging = false  (bool)
+   battery.reporting.current = 60000  (0xea60)  (int)
+   battery.reporting.design = 63360  (0xf780)  (int)
+   battery.reporting.last_full = 60090  (0xeaba)  (int)
+   battery.reporting.rate = 0  (0x0)  (int)
+   battery.reporting.technology = 'Li-ion'  (string)
+   battery.reporting.unit = 'mWh'  (string)
+   battery.serial = '   11'  (string)
+   battery.technology = 'lithium-ion'  (string)
+   battery.type = 'primary'  (string)
+   battery.vendor = 'FLT'  (string)
+   battery.voltage.current = 16618  (0x40ea)  (int)
+   battery.voltage.design = 14400  (0x3840)  (int)
+   battery.voltage.unit = 'mV'  (string)
+ GNOME Power Manager Process Information:
+ navado    5160  0.0  1.3  32612 17908 ?        Ss   Feb03   0:03 
gnome-power-manager
+ HAL Process Information:
+ 111       4624  0.1  0.3   6312  4260 ?        Ss   Feb03   0:04 
/usr/sbin/hald
+ root      4628  0.0  0.0   3364  1116 ?        S    Feb03   0:00  \_ 
hald-runner
+ root      4710  0.0  0.0   3436  1060 ?        S    Feb03   0:00      \_ 
hald-addon-input: Listening on /dev/input/event2 /dev/input/event5 
/dev/input/event3 /dev/input/event4 /dev/input/event1 /dev/input/event9
+ root      4721  0.0  0.0   3448  1040 ?        S    Feb03   0:00      \_ 
/usr/lib/hal/hald-addon-cpufreq
+ 111       4722  0.0  0.0   2296   944 ?        S    Feb03   0:00      \_ 
hald-addon-acpi: listening on acpid socket /var/run/acpid.socket

-- 
2-nd battary issues while batery powered
https://bugs.launchpad.net/bugs/325070
You received this bug notification because you are a member of Ubuntu
Desktop Bugs, which is subscribed to gnome-power-manager in ubuntu.

-- 
desktop-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/desktop-bugs

Reply via email to