** Attachment removed: "test scan showing the vertical band"
   
https://bugs.launchpad.net/ubuntu/+source/sane-backends/+bug/1863424/+attachment/5328427/+files/lide120.png

** Description changed:

+ THIS IS INCORRECT! I mis-remembered it working on 18.04 earlier.
+ 
+ SANE 1.0.29 properly fixes #1731459 for a LiDE 120 scanner.
+ ------------------------------------------------------ original report
+ 
+ 
  sane-backends (1.0.27-1~experimental3ubuntu2.2) brought a fix for a black 
vertical band on scans
  done with e.g. Canon LiDE 100 and 200 scanners on Ubuntu 18.04 as noted here:
  
-    sane-backends (1.0.27-1~experimental3ubuntu2.2) bionic;
+    sane-backends (1.0.27-1~experimental3ubuntu2.2) bionic;
  urgency=medium
  
-      * debian/patches/git-fix-discolored-bar-issue.patch:
-        - Upstream commit to fix issue with discolored bar on Genesys GL847
-          scanners (LP: #1731459).
+      * debian/patches/git-fix-discolored-bar-issue.patch:
+        - Upstream commit to fix issue with discolored bar on Genesys GL847
+          scanners (LP: #1731459).
  
-     -- Gunnar Hjalmarsson <gunna...@ubuntu.com>  Thu, 08 Aug 2019
+     -- Gunnar Hjalmarsson <gunna...@ubuntu.com>  Thu, 08 Aug 2019
  20:27:00 +0200
  
  However, on my Canon LiDE 120 it worked fine before that fix in 18.04, but 
now the image shows
  a discolored band at precisely the same location where on an LiDE 100/200 the 
black band
  used to be.
  
  See attached test scan for an example and compare with the uploads from
  https://bugs.launchpad.net/ubuntu/+source/sane-backends/+bug/1731459 .
  
  Affected are also daily builds of 20.04 from 2020-02-15.

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to sane-backends in Ubuntu.
https://bugs.launchpad.net/bugs/1863424

Title:
  Regression on Canon LiDE 120 by fix for #1731459

Status in sane-backends package in Ubuntu:
  Invalid

Bug description:
  THIS IS INCORRECT! I mis-remembered it working on 18.04 earlier.

  SANE 1.0.29 properly fixes #1731459 for a LiDE 120 scanner.
  ------------------------------------------------------ original report


  sane-backends (1.0.27-1~experimental3ubuntu2.2) brought a fix for a black 
vertical band on scans
  done with e.g. Canon LiDE 100 and 200 scanners on Ubuntu 18.04 as noted here:

     sane-backends (1.0.27-1~experimental3ubuntu2.2) bionic;
  urgency=medium

       * debian/patches/git-fix-discolored-bar-issue.patch:
         - Upstream commit to fix issue with discolored bar on Genesys GL847
           scanners (LP: #1731459).

      -- Gunnar Hjalmarsson <gunna...@ubuntu.com>  Thu, 08 Aug 2019
  20:27:00 +0200

  However, on my Canon LiDE 120 it worked fine before that fix in 18.04, but 
now the image shows
  a discolored band at precisely the same location where on an LiDE 100/200 the 
black band
  used to be.

  See attached test scan for an example and compare with the uploads from
  https://bugs.launchpad.net/ubuntu/+source/sane-backends/+bug/1731459 .

  Affected are also daily builds of 20.04 from 2020-02-15.

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/sane-backends/+bug/1863424/+subscriptions

-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to     : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp

Reply via email to