apport information

** Tags added: apport-collected wayland-session

** Description changed:

  When two displays are connected and one has a 200% scaling, moving apps
  between them results in several issues:
  
  Apps that can actively scale (such as native Nautilus, Settings...):
  
   When dragging the window around, it automatically adjusts scaling based
  on on which of the monitors is the majority of the app (this is probably
  correct behaviour),
  
  BUT when using keyboard shortcuts [Ctrl] + [Super] + ←/↑/↓/→, fullscreen
  windows jump around and scale correctly, but half-full screen apps
  (arranged by [Super] + ←/→) cannot go from the larger monitor to the
  smaller, they get stuck in the scaled-up version and don't fit on the
  smaller display.
  
  Small non-maximized windows don't have this issue, possibly because when
  they first move in their scaled-up state, they do fit on the smaller
  monitor still, and only then are they scaled down.
  
  
  Apps that don't support changes in scaling and only apply the new scaling on 
a relaunch (such as Chrome) don't have these issues, but they obviously have 
that other problem.
  
  
  Description:  Ubuntu 20.04.4 LTS
  Release:      20.04
  mutter 3.36.9
  
  What I expect:
  Windows covering half a full screen, when moved to a different display with 
different scaling (using a keyboard), stay covering half a full screen.
  
  What happens instead:
  When moved to a display with higher scaling, this happens correctly, but when 
moved to a monitor with lower scaling, they get "stuck" on both monitors in 
their inflated state.
+ --- 
+ ProblemType: Bug
+ ApportVersion: 2.20.11-0ubuntu27.24
+ Architecture: amd64
+ CasperMD5CheckResult: skip
+ CurrentDesktop: ubuntu:GNOME
+ DistroRelease: Ubuntu 20.04
+ InstallationDate: Installed on 2020-10-14 (658 days ago)
+ InstallationMedia: Ubuntu 20.04.1 LTS "Focal Fossa" - Release amd64 (20200731)
+ Package: mutter 3.36.9-0ubuntu0.20.04.2
+ PackageArchitecture: amd64
+ ProcVersionSignature: Ubuntu 5.15.0-43.46~20.04.1-generic 5.15.39
+ Tags:  focal wayland-session
+ Uname: Linux 5.15.0-43-generic x86_64
+ UpgradeStatus: No upgrade log present (probably fresh install)
+ UserGroups: adm cdrom dip lpadmin lxd plugdev sambashare sudo video
+ _MarkForUpload: True

** Attachment added: "Dependencies.txt"
   
https://bugs.launchpad.net/bugs/1983508/+attachment/5607034/+files/Dependencies.txt

-- 
You received this bug notification because you are a member of Desktop
Packages, which is subscribed to mutter in Ubuntu.
https://bugs.launchpad.net/bugs/1983508

Title:
  Moving windows between monitors with different scaling causes isues

Status in mutter package in Ubuntu:
  Incomplete

Bug description:
  When two displays are connected and one has a 200% scaling, moving
  apps between them results in several issues:

  Apps that can actively scale (such as native Nautilus, Settings...):

   When dragging the window around, it automatically adjusts scaling
  based on on which of the monitors is the majority of the app (this is
  probably correct behaviour),

  BUT when using keyboard shortcuts [Ctrl] + [Super] + ←/↑/↓/→,
  fullscreen windows jump around and scale correctly, but half-full
  screen apps (arranged by [Super] + ←/→) cannot go from the larger
  monitor to the smaller, they get stuck in the scaled-up version and
  don't fit on the smaller display.

  Small non-maximized windows don't have this issue, possibly because
  when they first move in their scaled-up state, they do fit on the
  smaller monitor still, and only then are they scaled down.

  
  Apps that don't support changes in scaling and only apply the new scaling on 
a relaunch (such as Chrome) don't have these issues, but they obviously have 
that other problem.

  
  Description:  Ubuntu 20.04.4 LTS
  Release:      20.04
  mutter 3.36.9

  What I expect:
  Windows covering half a full screen, when moved to a different display with 
different scaling (using a keyboard), stay covering half a full screen.

  What happens instead:
  When moved to a display with higher scaling, this happens correctly, but when 
moved to a monitor with lower scaling, they get "stuck" on both monitors in 
their inflated state.
  --- 
  ProblemType: Bug
  ApportVersion: 2.20.11-0ubuntu27.24
  Architecture: amd64
  CasperMD5CheckResult: skip
  CurrentDesktop: ubuntu:GNOME
  DistroRelease: Ubuntu 20.04
  InstallationDate: Installed on 2020-10-14 (658 days ago)
  InstallationMedia: Ubuntu 20.04.1 LTS "Focal Fossa" - Release amd64 (20200731)
  Package: mutter 3.36.9-0ubuntu0.20.04.2
  PackageArchitecture: amd64
  ProcVersionSignature: Ubuntu 5.15.0-43.46~20.04.1-generic 5.15.39
  Tags:  focal wayland-session
  Uname: Linux 5.15.0-43-generic x86_64
  UpgradeStatus: No upgrade log present (probably fresh install)
  UserGroups: adm cdrom dip lpadmin lxd plugdev sambashare sudo video
  _MarkForUpload: True

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/mutter/+bug/1983508/+subscriptions


-- 
Mailing list: https://launchpad.net/~desktop-packages
Post to     : desktop-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~desktop-packages
More help   : https://help.launchpad.net/ListHelp

Reply via email to