Github user franz1981 commented on the issue:

    https://github.com/apache/activemq-artemis/pull/2481
  
    I will be able to look into that in the next days :) 
    I can already ask you to collect time to safepoints/GC pauses if possible 
ie -XX:+PrintGCApplicationStoppedTime.
    2 minutes seems a too long period TBH, but worth taking a look if you rely 
on MAPPED journal and/or paging a lot, given that major page faulting can 
causes long stall similar to very long full GC, but TBH nothing so long (2 
minutes is a lot!).
    As an additional suggestion you could run a Java program that just use one 
core and jmeasure the elapsed time between 2 consecutive nanoTime calls, 
recording in which wall-clock time a back-ward "drift" has happened to check if 
a broker shutdown has happened near the same time, makes sense?



---

Reply via email to