Bhupesh. I would recommend reseting the variable in endWindow call and leaving it non-transient. Usually an empty variable should not add too much to serialization.
Thks, Amol On Sun, Nov 8, 2015 at 10:57 PM, Bhupesh Chawda <[email protected]> wrote: > Hi All, > > I have a question regarding maintaining state of a variable within a single > application window. > If I have a variable which is just needed for a single application window > (just between beginWindow and endWindow calls), do I need to serialize and > checkpoint it? or can I make it transient? > > I understand that in case of checkpoint windows being aligned with the > application windows, we can do so. Since in this case, the variable will > start afresh immediately after the checkpoint. However in case of > checkpoints happening in between application windows, this might not be the > case. > > In the second case, is there any mechanism using which I can conditionally > make it transient and non-transient based on when the checkpoints happen > with respect to the application windows? > > Thanks. > Bhupesh >