https://issues.apache.org/jira/browse/BROOKLYN-212?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Aled Sage resolved BROOKLYN-212.
--------------------------------
Resolution: Fixed
Fix Version/s: 0.9.0
> Auto-scaling in finite BYON cluster keeps adding on-fire entities
> -----------------------------------------------------------------
>
> Key: BROOKLYN-212
> URL: https://issues.apache.org/jira/browse/BROOKLYN-212
> Project: Brooklyn
> Issue Type: Bug
> Reporter: Aled Sage
> Fix For: 0.9.0
>
>
> When using a BYON location of a limited size (e.g. four vagrant VMs), if an
> auto-scaler policy tries to resize above this number of VMs then it goes
> badly wrong!
> Auto-scaling causes a new entity to be added to the cluster, but it fails to
> start because the {{location.obtain()}} call fails. That entity is left in
> quarantine, on-fire.
> The auto-scaler will then try again: another new entity is added, but this
> also fails. This repeats, adding more and more entities.
--
This message was sent by Atlassian JIRA