[ https://issues.apache.org/jira/browse/CAMEL-3834?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel ]
Hadrian Zbarcea resolved CAMEL-3834. ------------------------------------ Resolution: Fixed > SmppProducer sends incorrect data_coding parameter > -------------------------------------------------- > > Key: CAMEL-3834 > URL: https://issues.apache.org/jira/browse/CAMEL-3834 > Project: Camel > Issue Type: Bug > Components: camel-smpp > Affects Versions: 2.7.0 > Reporter: Steve Gansemer > Assignee: Christian Müller > Fix For: 2.7.2, 2.8.0 > > > The dataCoding parameter on the SMPP uri allows for a value of 0,4, or 8. > Our aggregator expects the data_coding parameter on the SMPP request from the > SmppProducer to be 0=SMSC Default Alphabet. However, when 0, 4, or 8 is > specified for the dataCoding parameter, the actual value sent on the smpp > request is 1, 5, or 9. It appears the MessageClass.Class1 on the > GeneralDataCoding object in SmppProducer is masking an additional 1 to the > byte value. > It seems the dataCoding parameter should allow you to specify the actual > value that is needed as defined by the SMPP Protocol specification. -- This message is automatically generated by JIRA. For more information on JIRA, see: http://www.atlassian.com/software/jira