On 7/31/2018 1:21 PM, Gavin Hu wrote:
Currently only one buffer pool is configured and in use, looping for up to maxmum 8 times is unnecessary and might be buggy as assigned uninititalized values.The fix is to loop for the configured times with initialize with valid values. Fixes: 16bbc98a3e ("bus/fslmc: update MC to 10.3.x") Cc: [email protected] Signed-off-by: Gavin Hu <[email protected]> Reviewed-by: Honnappa Nagarahalli <[email protected]> ---
Acked-by: Shreyansh Jain <[email protected]>