On 7/31/2018 1:21 PM, Gavin Hu wrote:
Currently only one buffer pool is configured and in use,
looping for up to maxmum 8 times is unnecessary and might
be buggy as assigned uninititalized values.

The fix is to loop for the configured times with initialize
with valid values.

Fixes: 16bbc98a3e ("bus/fslmc: update MC to 10.3.x")
Cc: [email protected]

Signed-off-by: Gavin Hu <[email protected]>
Reviewed-by: Honnappa Nagarahalli <[email protected]>
---

Acked-by: Shreyansh Jain <[email protected]>