Thanks Bernard .
Hi, Thomas, Ferruh, any other comments?
在 2021/4/29 17:07, Iremonger, Bernard 写道:
-----Original Message-----
From: Min Hu (Connor) <[email protected]>
Sent: Thursday, April 29, 2021 1:51 AM
To: [email protected]
Cc: Yigit, Ferruh <[email protected]>; Iremonger, Bernard
<[email protected]>; [email protected]
Subject: [PATCH v3 1/3] examples/flow_classify: fix check of port and core
According to the comments and logging, the author just hope user to use the
core and device which are in the same numa node for optimal performance.
If not, A warning gives out.
For example in flow_classify:
./build/flow_classify -a 0000:7d:00.1 -l 93
Here:
0000:7d:00.1 is on numa node 0.
core 93 is on numa node 3.
The two are not in same numa node, but no warning gives out in old codes.
This patch can fix it.
Fixes: bab16ddaf2c1 ("examples/flow_classify: add sample application")
Cc: [email protected]
Signed-off-by: Min Hu (Connor) <[email protected]>
Tested-by: Bernard Iremonger <[email protected]>
Acked-by: Bernard Iremonger <[email protected]>
.