dev_info.max_mac_addrs is of type uint32_t. But the counter i is
of type uint16_t. This mismatch may cause the loop condition may
always be true. Change the loop counter variable to uint32_t.

Fixes: b02f1573cd07 ("net/bnxt: restore MAC filters during reset recovery")
Cc: sta...@dpdk.org

Signed-off-by: Ajit Khaparde <ajit.khapa...@broadcom.com>
Reviewed-by: Kalesh AP <kalesh-anakkur.pura...@broadcom.com>
---
 drivers/net/bnxt/bnxt_ethdev.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/net/bnxt/bnxt_ethdev.c b/drivers/net/bnxt/bnxt_ethdev.c
index dba5b9f..6dfb33c 100644
--- a/drivers/net/bnxt/bnxt_ethdev.c
+++ b/drivers/net/bnxt/bnxt_ethdev.c
@@ -3959,7 +3959,7 @@ static int bnxt_restore_mac_filters(struct bnxt *bp)
        struct rte_ether_addr *addr;
        uint64_t pool_mask;
        uint32_t pool = 0;
-       uint16_t i;
+       uint32_t i;
        int rc;
 
        if (BNXT_VF(bp) && !BNXT_VF_IS_TRUSTED(bp))
-- 
1.8.3.1