On 10/28/2021 12:52 PM, Min Hu (Connor) wrote:
Mailbox is the communication mechanism between SW and HW. There exist two approaches for SW to recongnize mailbox message from HW. One way is using match_id, the other is to compare the message code. The two approaches are independent and used in different scenarios.But for the second approache, "next_to_use" should be updated and written to HW register. If it not done, HW do not know the position SW steps, then, the communication between SW and HW will turn to be failed. Fixes: dbbbad23e380 ("net/hns3: fix VF handling LSC event in secondary process") Cc: [email protected] Signed-off-by: Min Hu (Connor) <[email protected]>
Applied to dpdk-next-net/main, thanks.